VM-6370 Digital Vibration Meter VM6370
Click Image for Gallery
The lead time is about 3 business days, and shipping time by FedEx is about 5-7 days.
•Is pecifically designed for present measuring various mechanical vibration. So as to provde the data for the quality control, run time and equipment upkeep.
•use the high-performance acceleration meter, realize the repetitiveness and accurate measurement.
•It has the function of displaying "Velocity, Acceleration, Displacement" in same time.
Measurement Range:
Velocity: 0.01-400.0 mm/s 0.000-16.00 inch/s true RMS
Acceleration: 0.1-400.0 m/s² 0.3-1312 ft/s² 0.0-40g equivalent peak
Displacement:0.001-4.000mm 0.04-160.0 mil equivalent peak-peak
Frequency Range for Measuring:10Hz. to 10kHz.
Accuracy:5% of reading + 2 digits
Metric/ Imperial conversion
Analogue Output: AC output 0~2.0V peak full scale (load resistance: above 10k)
With Max. value hold and low battery indication
PC interface: RS232C or Bluetooth interface ( Cable and software is not included)
Power supply: 2x1.5v AA size (UM-3) batteries
Power off : Manual off at any time or auto power off is enabled by user
Operating conditions:
Temperature : 0-50 ℃
Humidity : below 95% RH
Accelerometer
Stinger probe (Cone)
Stinger probe (Ball)
Carrying case
Operation manual
•Cable and software for RS232C
Introduction:
•Used for measuring periodic motion, to check the imbalance and deflecting of moving machinery.•Is pecifically designed for present measuring various mechanical vibration. So as to provde the data for the quality control, run time and equipment upkeep.
•use the high-performance acceleration meter, realize the repetitiveness and accurate measurement.
•It has the function of displaying "Velocity, Acceleration, Displacement" in same time.
Specfications:
Display:4 digit LCD backlitMeasurement Range:
Velocity: 0.01-400.0 mm/s 0.000-16.00 inch/s true RMS
Acceleration: 0.1-400.0 m/s² 0.3-1312 ft/s² 0.0-40g equivalent peak
Displacement:0.001-4.000mm 0.04-160.0 mil equivalent peak-peak
Frequency Range for Measuring:10Hz. to 10kHz.
Accuracy:5% of reading + 2 digits
Metric/ Imperial conversion
Analogue Output: AC output 0~2.0V peak full scale (load resistance: above 10k)
With Max. value hold and low battery indication
PC interface: RS232C or Bluetooth interface ( Cable and software is not included)
Power supply: 2x1.5v AA size (UM-3) batteries
Power off : Manual off at any time or auto power off is enabled by user
Operating conditions:
Temperature : 0-50 ℃
Humidity : below 95% RH
Standard Accessories:
Powerful rare earth magnetAccelerometer
Stinger probe (Cone)
Stinger probe (Ball)
Carrying case
Operation manual
Optional accessories:
•Headphones for use as electronic stethoscope•Cable and software for RS232C
- Dimensions: 124x62x30mm/4.9x2.4x1.2 inch
- Weight: 120g (not including batteries)